Room sensor and rear shield installation, Room sensor installation, Rear shields – Harman Stove Company HARMAN P68 User Manual

Page 21

Advertising
background image

21

P68 Pellet Stove

3-90-00688R24_06/13

The room sensor is a small temperature sensor on the end of

a 60" wire. This sensor is installed much like a standard wall

thermostat. Because it is so small, it can be hidden along the

trim of a doorway or even up the leg of a coffee table. There

is a remote room sensor port on the rear of the unit for easy

external connection. Use standard 18-2 thermostat wire to

extend the distance to the desired location (50' maximum).

The room sensor should be installed in the location where

you want to control the temperature.
In most installations locating the room sensor behind the

stove near the distribution fan works well because the sensor

monitors the room air being drawn into the distribution fan.
note: Distances of more than 25 feet from the unit or in

another room are not recommended. The room sensor is

essential for the P68's excellent efficiency.
note: it is recommended that the room sensor be

installed, even if only installed on the rear of the unit as a

return air sensor.

Fig. 24

room sensor installation

Fig. 25

room sensor and rear shield installation

rear shields

5/16" Hex Head

Screws (3 on

each side)

5/16" Hex Head

Screws (3 on

each side)

The rear shields are split in the middle for easy removal.

Each shield has (3) 5/16" hex head screws. Two (2) that only

need to be loosened, and one (1) that needs to be completely

removed, to allow the shield to slide away from the unit.
note: it is not recommended that the unit be operated

with the shields removed, due to the hot and moving

parts which they protect.

Room

Sensor

Port

Advertising