P68 Pellet Stove

3-90-00688R24_06/13

autoMatic ignition esP control

Feed adjuster

Sets the maximum feed

rate

Test

Runs all motors at full

speed for one minute

t o c h e c k o p e r a t i o n .

Afterwards, it will simulate

a minimum burn and the

combustion blower will

remain on low.

Distribution Blower

speed adjustment

range.

L = low

H = high

Variable speed anywhere

between L and H; although

as the stove temp. goes up,

so does the low end of the

scale.

Temp dial

Allows you to adjust the room temperature in Room

Temp Mode using the outer scale marked in degrees

Fahrenheit. It also allows you to adjust the stove

temperature while in Stove Temp Mode using the

inner scale marked from 1 to 7.

Mode Selector

Allows you to choose between

Room Temp Mode, Stove Temp

Mode, or OFF. Also allows you

to vary the distribution blower

speed by turning the knob to the

high or low side of each mode.

Power Light

Indicates power to the

control.

Indicates power to the

feed motor.

Indicates power to the

igniter

Indicates power to

combustion blower

Status Light

Will be lit in either stove

or room temp mode

when pointer is not

within off position band

except after normal shut

down. Blinks to indicate

errors listed below.

Indicates power to

distribution blower.

status light error messages:
3 blinks:
Indicates an incomplete ESP circuit, or that the ESP

(Exhaust Sensing Probe) Has gone out of range a specific

number of times. This may indicate the need for cleaning

the exhaust. Perform a manual reset*. If the code persists,

contact your dealer.
4 blinks: Can occur only in Room Temp Mode and

indicates Room Sensing Probe failed or not installed. If a

Room Sensing Probe is then installed, the status light will

automatically reset.
5 blinks (in igniter auto. Mode only): Indicates that the unit

has failed to light within the 36 minute start cycle. To reset -

Turn Mode Selector to "OFF", then turn to either mode again.

6 blinks : Indicates that the control has calculated poor or

incomplete combustion occurring for more than 25 minutes.
A six blink status may be set if the stove is allowed to run out

of pellets. To reset, turn mode selector to "OFF" then back

on to the desired mode. If the unit was not out of pellets, see

Troubleshooting section, Page 28, for more details.
* Manual reset- disconnect power cord for a few seconds

and reconnect. If error still occurs call your Dealer.

Dealer Diagnostic Port

For dealer maintenance

only. Requires special

DDM monitor supplied

t o H a r m a n D e a l e r s

exclusively.

Igniter switch

Set to appropriate Start-

Up mode.