Automatic ignition/operation – Harman Stove Company HARMAN P68 User Manual

Page 15

Advertising
background image

15

P68 Pellet Stove

3-90-00688R24_06/13

autoMatic ignition/oPeration

The setting above will produce continuous maximum heat output

with the distribution blower at full speed.

stove temperature Mode

The setting above will produce continuous medium heat output

with the distribution blower at low speed.

shut down Procedure

The best way to shut down the stove is simply let it run out of

pellets. The stove will shut down automatically. Alternatively,

you can turn the Mode Selector to “off”. This will cause the

fire to gradually die down and go out. The fire will not go

out immediately and may take more than an hour to fully

shut down.
If the stove is left to run out of fuel, you may get a 6 blink

status light. If this happens simply reset the control board by

turning the mode selector to OFF and back ON.

stove temperature Mode

In the Stove Temperature Mode and with the igniter toggle

switch in the Auto position, the stove will light automatically

and can be adjusted to the desired setting using the same

temperature control dial as is used in the Room Temperature

Mode. The heat output and fuel consumption will remain

constant regardless of room temperature. The settings from

1 to 7 on the inner ring of the dial provide for relative heat

output settings with 1 being low and 7 being the maximum.
In Stove Temperature Mode, the stove will not automatically

shut off unless the stove runs out of fuel or is turned off.
never pull the plug to shut down the stove. This will stop the

combustion blower and smoke will escape through window

and door gaskets.
When the igniter toggle switch is set to manual in this mode,

the distribution blower will not turn on with a temperature dial

setting from 1 to 5. The advantage of this mode is to allow

the operator to have a large viewing fire without blowing extra

heat into the room.
During manual operation, with the temperature dial set

at #4 or less, the distribution fan will not operate. A #4

on the temperature dial and a #5 on the feed adjuster is

approximately 80% output. It is not necessary to operate the

distribution blower below this point. Therefore, the control

allows a higher burn rate ( a larger viewing fire) without an

excess of hot air blowing into the room.
An example of when to use the Manual Stove Temperature

Mode is if you want to watch a large fire and the room is

already up to temperature. The Stove Temperature Mode

allows you to have a larger fire and a lower sound level,

without the distribution blower.
note: during the use of this mode, if you keep increasing

the temperature dial setting to increase the fire size, the

distribution blower will automatically come on when the

esP temperature reaches 350o F, or 81% output.
Feed adjuster Knob

For most premium grade pellet fuels the Feed Adjuster Knob

should be set at 4. If higher ash fuels are used the setting

should be increased to 5 or 6. Also higher settings are

required if you would like to get the maximum heat output from

the stove. At the maximum burn rate (with the temperature

dial on 7/90° and the feed adjuster at 6) there should be 1" or

more of ash on the front of the burn pot. If there is less than

1" of ash, turn the feed adjuster knob down to a lower setting.

Advertising