Model OFE/OFG/OEA/OGA-341, 342



2-7. GAS LEAK TEST


Prior to turning the gas supply on, be sure the gas valve
knob on the gas control valve is in the OFF position.

Upon initial installation, and after moving the unit, the piping

and fittings should be checked for gas leaks. A simple

checking method is to turn on the gas and brush all

connections with a soap solution. If bubbles occur, it

indicates escaping gas.

To avoid fire or explosion, never use a lighted match or

open flame to test for gas leaks. ignited gas could result

in severe personal injury and/or property damage.

2-8. PRESSURE REGULATOR

The gas pressure regulator on the automatic gas valve is

factory set as follows:


• Natural: 3.5 inches water column (8.7 mbar).

• Propane 10.0 inches water column (24.9 mbar).


The gas pressure regulator has been set by Henny

Penny and is not to be adjusted by the user.


2-9. ELECTRICAL

• 120 V, 60 Hz., 12 A, 1 PH

REQUIREMENTS

• 230 V, 50 Hz., 6.2 A, 1 PH

OFG/OGA-340 SERIES

The 120 V gas fry station requires a 3 wire grounded

(Earthed) service and is supplied with a grounded cord and

plug. Any 230-volt plug used on the 230-volt unit must

conform to all local, state, and national codes.




To avoid electrical shock, this appliance must be

equipped with an external circuit breaker which will

disconnect all ungrounded (unearthed) conductors.

The main power switch on this appliance does not

disconnect all line conductors.