Henny Penny OFE-341 User Manual

Page 7

Advertising
background image

Model OFE/OFG/OEA/OGA-341, 342



2-9. ELECTRICAL

REQUIREMENTS

OFG/OGA-340 SERIES

(Continued)

To avoid electrical shock, do not disconnect the ground

(earth)

plug. This fryer must be adequately and safely

grounded. Refer to local electrical codes for correct

grounding (Earthing) proceduresor in absence of local

codes, with the National Electrical Code, ANSI/NFPA

No. 70 Latest Edition. Canadian models are supplied

with a terminal box, suitable for conduit connection. In

Canada, all electrical connections are to be made in

accordance with CSA C221, Canadian Electrical

Code Part 1, and/or local codes.

2-10. ELECTRICAL

Refer to the table below for supply wiring and fusing.

REQUIREMENTS

(Per Well)

OFE/OEA-340 SERIES

Volts

Phase

Kw

Amps

208

3

22.0

61

240

3

22.0

53

380-415 3N+G

22.0

32.5



To avoid electrical shock, this appliance must be

equipped with an external circuit breaker which will

disconnect all ungrounded (unearthed) conductors.

The main power switch on this appliance does not

disconnect all line conductors.


To avoid electrical shock, this fryer must be

adequately and safely grounded (earthed). Refer to

local electrical codes for correct grounding (earthing)

procedures or in absence of local codes, with The

National Electrical Code, ANSI/NFPA No. 70-(the

current edition). In Canada, all electrical connections are

to be made in accordance with CSA C22.1, Canadian

Electrical Code Part 1, and/or local codes.


CE units require a minimum wire size of 6mm to be wired to the

terminal block. If a flexible power cord is used, it must be

HO7RN

type.


Permanently connected electric fryers with casters must be

installed with flexible conduit and a cable restraint, when installed

in the United States. See illustration at left. Holes are available in

the rear fryer frame for securing the cable restraint to the fryer.

The cable restraint does not prevent the fryer from tipping.

2-7

705

DRYWALL CONSTRUCTION
Secure I-bolt to a building stud. Do
not attach to drywall only. Preferred
installation is approximately six
inches to either side of service.
Cable restraint must be at least six
inches shorter than flexible conduit.

Advertising