Water-cooled condenser – Hoshizaki KM-650MAH User Manual

Page 22

Advertising
background image

22

2. Water-Cooled Condenser

a) Connection to an Open Drain System
• Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD

copper tubing is recommended for the condenser water supply line.

• A condenser water supply line shut-off valve and drain valve should be installed.
• Condenser drain outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for

the condenser drain line.

• In some areas, a back flow preventer may be required in the cooling water circuit.

Fig. 13

KM-650MWH

Connection to an Open Drain System

Separate piping to approved drain.
Leave a two-inch (5 cm) vertical air
gap between the end of each pipe
and the drain.

Icemaker Water Supply Line

Shut-Off Valve

Icemaker Water Supply Line

Drain Valve

Icemaker

Icemaker Water

Supply Inlet

1/2" FPT

Bin Drain Outlet

3/4" FPT

Two-inch

(5 cm) air

gap

Floor Drain

Icemaker

Drain Outlet

3/4" FPT

Bin

Condenser Water Supply Line

Shut-Off Valve

Condenser Water Supply Line

Drain Valve

Condenser Water

Supply Inlet

1/2" FPT

Condenser

Drain Outlet

3/8" FPT

Condensation

Drain Outlet

3/8" OD Stainless

Tube

Advertising