Hoshizaki KM-650MAH User Manual

Page 31

Advertising
background image

31

5) Open the water regulating valve by using a screwdriver to pry up on the spring retainer

underneath the spring. While holding the valve open, blow out the condenser using the
compressed air or carbon dioxide supply until water stops coming out.

6) Close the drain valve(s).
7) Replace the right side panel and front panel in their correct positions.

Advertising
This manual is related to the following products: