Operating instructions, Shutdown procedure, First fire – Hampton Direct H35-NG1 User Manual

Page 39: Final check, Lighting procedure

Advertising
background image

Hampton

®

H35 Direct Vent Freestanding Gas Stove

39

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

1) Read and understand these instructions

before operating this appliance.

2) Check to see that all wiring is correct and

enclosed to prevent possible shock.

3) Check to ensure there are no gas leaks.

4) Make sure the glass in the door frame is

properly positioned. Never operate the ap-
pliance with the glass removed. Never strike
the glass or slam the door shut.

5) Verify that the venting and cap are unob-

structed.

6) Verify log placement. If the pilot cannot be

4) When the pilot stays lit, turn the gas knob

further counterclockwise to the "ON" posi-
tion.

5) Use the thermostat or remote control to turn

on the unit.

6) Rotate the fl ame height regulator to adjust

the fl ame height higher or lower.

SHUTDOWN

PROCEDURE

1) Use the thermostat or remote control to turn

off the main burner.

2) Turn the main gas control clockwise to the

"OFF" position to turn off the pilot (push
knob in slightly).

3) Turn off all electric power to appliance if

service is to be performed.

FIRST FIRE

The FIRST FIRE in your stove is part of the
paint curing process. To ensure that the paint is
properly cured, it is recommended that you burn
your fi replace for at least four (4) hours the fi rst
time you use it with the fan on. When fi rst oper-
ated, the unit will release an odour caused by the
curing of the paint and the burning off of any oils
remaining from manufacturing. Smoke detectors
in the house may go off at this time. Open a few
windows to ventilate the room for a couple of
hours. The glass may require cleaning.

DO NOT ATTEMPT TO CLEAN THE GLASS

WHILE IT IS STILL HOT!

Note: When the glass is cold and the appli-

ance is lit, it may cause condensation
and fog the glass. This condensation
is normal and will disappear in a few
minutes as the glass heats up.

DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.

During the fi rst few fi res, a white fi lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the fi lm will bake on and
become very diffi cult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.

seen when lighting the unit - the logs have
been incorrectly positioned.

7) The unit should never be turned off, and on

again without a minimum of a 60 second
wait.

1) Choose a convenient location on the wall

to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location, use Thermostat Wire Table.

2) Connect the wires as per the wiring diagram

below.

CAUTION

Do not connect the

millivolt remote control wires

to the 120V wires.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:

1) Clocking the appliance to ensure the cor-

rect fi ring rate (rate noted on label) at 15
minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow
the unit to burn for 15 min. to stabilize.

3) Check

for

proper

draft.

CAUTION

Any alteration to the product that causes
sooting or carboning that results in damage
to the exterior facia is not the responsibility
of the manufacturer.

LIGHTING

PROCEDURE

IMPORTANT: Gas on/off knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.

1) Turn stove OFF using the Burner "ON/OFF"

switch remote or thermostat.

2) Turn gas control knob so indicator points

to "OFF" position and allow 5 minutes for
any gas in the combustion chamber to
escape.

3) Turn gas control knob counterclockwise

so indicator points to the "PILOT" position.
Depress the gas control knob fully. Depress
the igniter button several times until the
pilot lights. After approximately one minute,
release the gas control knob. The pilot fl ame
should continue to burn. If the pilot does not
remain lit, repeat operation allowing a longer
period before releasing gas control knob.

IMPORTANT

To ignite or reignite the pilot,

the door to the fi rebox must

be opened.

Only when the pilot holds, without pressure
being applied to the control knob, should the
door to the fi rebox be closed. The unit must
never
be operated with the glass or door
open.

NOTE: For all propane units and units
equipped with electric spark boxes, see
"Copy of Lighting Plate Instructions" sec-
tion for more details.

Advertising