WaterMax 60 Series Owner’s Manual

11/10/2008

19

Service Settings, Cont.

Mode 1 (Timer Mode) Setting Chart

This section provides guidance for using different service settings to achieve the desired capacity.

60 Series

63MAQ

1

63BEQ

1,2

63MXQ

1

63MDQ

62AMQ

1

62APQ

1,3,4

62AKQ

62AJQ

5

Mode 1

Yes Yes Yes Yes Yes Yes Yes Yes

Regeneration Frequency

As

required

As

required

As

required

1 or 2

days

As

required

1 or 2

days

1 or 2

days

1 or 2

days

96 hour regeneration
(if iron present—yes)

6

— — Yes — Yes — — —

#1 Salt Setting

Backwash 1 (minutes)

1

1

1

6

— 2

6

— — —

Brine/Rinse

(minutes) 7 7 7 — 7 — — —

Backwash 2 (minutes)

3

3

3

2

Capacity (grains) @
salt (lb)

5,900 @

1.1 lb

5,900 @

1.1 lb

8,400 @

1.6 lb

5,200 @

1 lb

— — —

#2 Salt Setting

Backwash 1 (minutes)

1

1

1

6

— 2

6

— — 7

6

Brine/Rinse

(minutes) 12 12 19 — 12 — — 12

Backwash 2 (minutes)

3

3

3

2

2

Capacity (grains) @
salt (lb)

16,300 @

3.2 lb

16,300 @

3.2 lb

20,000 @

4.2 lb

11,900 @

2.7 lb

— —

11,900 @

2.7 lb

#3 Salt Setting

Backwash 1 (minutes)

1

1

1

7

1 2

7

7 7 7

Brine/Rinse

(minutes) 30 30 47 38 30 30 30 30

Backwash

2

(minutes) 3 3 3 3 2 2 2 2

Capacity (grains) @
salt (lb)

26,700 @

6.2 lb

26,700 @

6.2 lb

38,700 @

9.6 lb

23,100 @

8.5 lb

23,100 @

6.2 lb

23,100 @

6.2 lb

23,100 @

6.2 lb

23,100 @

6.2 lb

#4 Salt Setting

8

Backwash 1 (minutes)

1

1

1

7

1 4

7

7 7 7

Brine/Rinse

(minutes) 45 45 60 45 45 45 45 45

Backwash

2

(minutes) 3 3 3 3 2 2 2 2

Capacity (grains) @
salt (lb)

32,500 @

9.5 lb

32,500 @

9.5 lb

49,300 @

14.4 lb

30,300 @

10.7 lb

30,000@

9.3 lb

29,800 @

9.3 lb

30,300 @

9.3 lb

30,300 @

9.3 lb

1

Models 63MAQ, 63BEQ, 63MXQ, 62AMQ and 62APQ are certified by

WQA. All other models are not tested or certified by WQA.

2

Municipally supplied chlorinated water only.

3

Must have a minimum of 2 ppm iron and a minimum of 200 ppm TDS.

See

Specifications.

4

Model has no backwash flow control button or retainer. Must have a

minimum of 7 gpm @ 30 psi available for proper backwash.

5

Calcite will add additional hardness to water before softening.

6

If iron is present in water supply, use salt setting #3 or #4.

7

If iron is present in the water supply, set Backwash 1 to 7 minutes.

8

Do not use this salt setting in California.