Installation, Operation and maintenance – FMI F48H(I)(R) User Manual

Page 16

Advertising
background image

www.fmiproducts.com

122272-01D

16

Figure 24 - Installing Doors

Figure 25 - Adjusting Bi-Fold Doors

installation

Continued

Bottom

Retaining

Clip

Slide Top

Pin Into Top

Retaining Clip

Spring Clip

Side Front

Face

Partially

Opened

Door

opeRation and Maintenance

GLASS DOORS

Glass doors are optional with fireplace. When

fireplace is in operation, doors must be fully

opened or fully closed position only or a fire

hazard may be created (see Figure 26).
A fireplace equipped with glass doors oper-

ates much differently than a fireplace with an

open front. A fireplace with glass doors has a

limited amount of air for combustion.
Excessive heat within the fireplace can result if

too large a fire is built or if combustion air gate is

not completely open. The following tips should

be followed to assure that both the fireplace

and glass door retain their beauty and func-

tion properly. Both the flue damper and glass

doors must be fully opened before starting fire.

This will provide sufficient combustion air and

maintain safe temperatures in firebox.

Figure 26 - Bi-Fold Glass Doors

Doors Fully Closed

Fireplace Front

Fireplace Front

Doors

Fully Opened

Installing Glass Doors

After spring clips have been installed some

adjustments may be needed. Install the doors

using the following steps:
1. With bi-fold doors completely folded, insert

bottom pivot pin into bottom retaining clip

located at far left and far right side of bot-

tom rail. Swing door to vertical position

making sure top pins slide into top door rail.

Door is installed when top door pin snaps

into spring clip (see Figure 24).

2. Repeat step 1 for remaining door.
If you find the doors do not close properly or

do not appear level or straight, proceed with

section on door adjustment.

DOOR ADjUSTMENT

Remove doors and slightly loosen upper spring

clips. Replace and fully close doors. Use 1/8"

shims (any material) to level doors. Once proper

setting is achieved, carefully open doors enough

to access top retaining clips with a phillips

screwdriver. Tighten screws. See Figure 25.