Electrical requirements, Window installation, Through-the-wall installation – Friedrich CP24F30 User Manual

Page 6

Advertising
background image

B

C

C

A

D

Power supply
cord

Wiring requirements

115-volt (103.5 min. - 126.5 max.)

0-12 amps

15-amp time-delay fuse or circuit breaker

Use on single outlet circuit only.

230-volt (207 min. - 253 max.)

0-12 amps

15-amp time-delay fuse or circuit breaker

Use on single outlet circuit only.

¹⁄₄"

(0.6 cm)

The wall opening measurements should be:

Height (A): 17 ¼" plus twice thickness of wood used to build
frame

Width (B): 26 ¼"

Depth (D): 4" minimum to 8" maximum.

Electrical Requirements

Ground wire must be connected to ground screw located in lower
right corner of air conditioner when air conditioner is in cabinet.

The electrical ratings for your air conditioner are listed on the
model and serial number (nameplate) label. The model and serial
number label is located behind the front panel on the flange below
the control panel area.

Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.

Window installation

Window opening measurements:

27"min. to 42" max. (76.2 cm to 101.6 cm) opening width (A).

20" min. (50.8 cm) opening height (B).

Through-the-wall installation

A.27" min. (76.2 c m)
B . 20" min. (50.8 c m)

A

B

A. 17 ¼"
B. 26 ¼"

C. Wood thickness
D. 4" minimum to

8" maximum.

CP1

5

CP18 / CP24

4