Frymaster 17EC User Manual

Page 13

Advertising
background image

2-3

Whichever option is chosen, Teflon thread-seal tape, Loctite™ PST56765 or equivalent
thread sealer must be used when installing the fittings.

NOTE: Depending on specific model ordered, either hot or cold water, or both, may be
connected to the unit. If available, connecting hot water will minimize the time required to
bring the unit to a boil when filling with fresh water.

NOTE: In order for the water level sensors to work properly, a certain amount of mineral
content in necessary in the water. For that reason, purified, deionized, or highly filtered
water should not be used.

5. Connect the desired drain plumbing to the drain valve.

2.4

Connecting to the Electrical Supply

DANGER

This unit must be connected to the voltage and phase specified on the rating and serial

number plate located on the inside of the equipment door. To determine the appropriate

wire size, refer to the POWER REQUIREMENTS chart at the bottom of this page.

1. If the unit is not equipped with an installed power cord, open the door and remove the contactor

box cover. Position the unit to gain access to the rear and remove the lower back panel.

2. Insert an appropriately rated power cord into the rear of the contactor box and make connections

in accordance with the applicable wiring diagram on the following page. Install a strain relief on
the power cord and replace the lower back panel and contactor box cover.

3. Attach a plug that complies with national and/or applicable local codes to the free end of the

electrical power cord and plug the unit into an appropriate outlet.

POWER REQUIREMENTS

Use copper wire ONLY, suitable for at least 170ºF (75ºC)

ELECTRIC COOKER MODELS 17EC, 17ECS, ESW, & EWBS

Volts

Phase

Watts

Amps

(per leg)

Minimum

Wire Size

200

Single

7860

40

AWG 6 (4.1 mm)

200

Single

12000

60

AWG 4 (5.2 mm)

208

Single

8500

41

AWG 6 (4.1 mm)

208

Single

13000

63

AWG 4 (5.2 mm)

208

3P – Delta

8500

48

AWG 8 (3.3 mm)

200

3P – Delta

12000

35

AWG 6 (4.1 mm)

208

3P – Delta

13000

37

AWG 6 (4.1 mm)

230

3P – Delta

13000

33

AWG 6 (4.1 mm)

200

3P – Wye

12000

21

AWG 8 (3.3 mm)

230

3P – Wye

13000

19

AWG 8 (3.3 mm)