TROUBLESHOOTING THE WATER HEATING SYSTEM

Each of the following checks is to be performed with the unit connected to the
electrical power supply, with the unit ON and calling for heat, and with at least
enough water in the cookpot to cover the lower water-level sensor.

Is resistance

between outside

terminals

1 ohm or less?

High-limit has

failed. Replace.

High-limit is OK.

Yes

No

CHECKING THE

HIGH-LIMIT

THERMOSTAT

CHECKING THE

ELEMENT

(24VAC Power Supply

verified to be OK..)

Was there an

audible snap indicating the

contactor coil

energized?

No

Yes

With sufficient water in the cookpot to cover the

heating element, place the POWER switch in
the ON position and the CYCLE switch in the

SIMMER position, OR press the computer ON/

OFF switch to the ON position.

Ohm out elements (Pins 1 & 6,

2 & 5, 3 & 4). If resistance

is NOT 15 ±3 Ohms, the element

has failed. Replace.

Is 24VAC

present on the
CYCLE switch

OR

on Pin 4 of the 15-pin

connector on

the IFB.

Probable causes,

in order of probabilty,

are failed switch or

contactor.

Probable causes, in

order of probabilty, are

failed computer or IFB.

Yes

No

CHECKING

THE TEMPERATURE

PROBE

(on units with computers

because water boils in

Simmer Mode or water is

too cool in Simmer Mode.)

Check probe resistance between Pins 6
a n d 8 o n I F B 1 2 - p i n c o n n e c t o r .
Resistance should be:
Approx 552 ohms @ 60ºF (16ºC)
Approx 655 ohms @ 100ºF (38ºC)
Approx 1000 ohms @ 212ºF (100ºC)
Check resistance between each pin and
ground. Resistance on BOTH should be
2 mega-Ohms or greater.

Are BOTH readings

within specification?

Probe is open or is

shorted. Replace.

Probe is OK.

No

Yes

CHECKING

THE THERMOSTAT

(on units with manual

controls.)

Set thermostat knob to OFF position.
Check resistance across terminals.
Resistance should be infinite.

Set thermostat to its highest setting.
Check resistance across terminals.
Resistance should be less than 1 ohm.

Are BOTH

readings correct?

Thermostat is open or

is shorted. Replace.

Thermostat

is OK.