6.4.6 Technician Troubleshooting Guides

TROUBLESHOOTING THE 24VAC POWER SUPPLY SYSTEM

Is 24VAC

present on the load side of

the transformer?

Transformer has

failed. Replace.

24VAC Power Supply

System is OK.

Causes are broken or loose wiring

or a failed contactor. If wiring and

connections are verified to be intact,

replace contactor.

Place the master ON/
OFF switch in the ON

position.

Was there an

audible snap from the

contactor indicating the

coil energized?

Yes

Is 24VAC present

across Pins 1and 2

of the 15-pin connector

on the front of the

contactor box?

No

No

Yes

Yes

Verify continuity of

master ON/OFF switch in ON position.

Replace switch as required.

If switch is OK, causes are broken

or loose wiring. Check connections and

replace wiring as required.

Yes

The primary indicator of a
problem with the 24VAC
Power Supply System is a
failure of the computer to
activate when the master
ON/OFF switch is placed
in the ON position and the
computer ON/OFF switch
is pressed.

Verify that the power cord is

properly connected to the
electrical service and that

the circuit breaker is not

tripped.

Is line voltage

present on the line side of

the transformer?

No

Check 5-amp transformer

fuse. Replace if blown. If fuse

is OK, cause is loose or broken

wiring, or the electrical service

circuit is dead.

No