TROUBLESHOOTING THE BASKET LIFT SYSTEM

If the basket lift motors are activating, but the basket lift fails to raise
or lower, or if its movement is erratic, the probable cause is
jamming or binding of the basket lift rods. Apply a light-weight white
grease (such as Lubriplate

TM

) to the rods. If this does not correct

the problem, check for bent or otherwise damaged rods and links,
and for loose bellcranks.

TROUBLESHOOTING

THE BASKET LIFT

With the basket lift

in the UP position, is 27-33VDC

present at Pin 7 or 9 of IFB 15-pin

connector (0 volts if in DOWN

position)?

Computer has failed.

Replace.

No

Yes

Yes

With the basket lift in the same

position as for the previous check, is

line voltage present at the Common

terminal of the switch?

With the basket lift

in the UP position, is line voltage

present at the NC (lower) terminal of
the microswitch (middle terminal if in

DOWN position)?

IFB has failed.

Replace.

No

Switch has failed.

Replace.

No

Motor has failed.

Replace.

Yes