Figure 7 - Fireplace Settings (Default Settings are Circled)

FLAME

Off Low Medium High

EMBER

Off Low Medium High

HEATER

Off On

CLEANING AND MAINTENANCE

WARNING: Always discon-

nect power and allow the heater

to cool before performing any

cleaning, maintenance or reloca-

tion of this heater. Turn controls

to OFF and remove plug from

outlet or turn off circuit breaker

to heater.

To service electric fireplace it may be neces-

sary to remove it from the mantel or enclosure

in which it is installed. Let unit cool completely

before cleaning or servicing.

CLEANING FIREBOx

1. Open control panel door by pressing on

right side. A spring magnet will push door

forward. Pull door down to open.

2. Remove 2 screws holding front trim in

place. Pull gently to remove trim (see

Figure 8). There are magnets on the lower

portion of trim (see Figure 8)

3. With gloves and safety glasses in place,

remove 4 screws from glass retainer

brackets (2 per bracket).

4. Carefully remove front glass and brackets

(see Figure 9).

5. Using a brush vacuum attachment, gently

clean compartment.

6. After cleaning compartment, replace front

glass, screw, bracket and trim.

Figure 9 - Removing Brackets and Front

Glass

Bracket

Front Glass

Figure 8 - Removing Trim

Magnets on

Back of Trim

Screws

Bracket

Screws

Trim

Control Panel Door