FUJITSU MAG3091FC User Manual

Page 53

Advertising
background image

C141-E078-02EN

4 - 6

(2)

Limitation of side-mounting

Mount the side using the screw holes at both the ends as shown in Figure 4.5. Do not use the
center hole.

Figure 4.5

Limitation of side-mounting

(3)

Environmental temperature

Temperature condition at installed in a cabinet is indicated with ambient temperature measured 3
cm from the disk drive. At designing the system cabinet, consider following points.

Make a suitable air flow so that the DE surface temperature does not exceed 55°C.

CAUTION

An air flow with an adequate wind velocity must be maintained to
deal with much heat generated from the MAC30xxFC.
Reference value: An air flow with a wind velocity of more than 0.5

m/s is required in an environment at 40°C, and
an air flow with a wind velocity of more than
1.0m/s in an environment at 45°C (Center of DE
cover

55°C).

Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling
effect by measuring temperature of specific ICs and the DE. These measurement results
should be within a criteria listed in Table 4.1.

Holes for mounting screw
Use these holes (No. 1 to 4)
to mount.

Do not use these holes

2

1

3

4

Holes for
mounting
screw