Frymaster SR52 & SR62 User Manual

Page 7

Advertising
background image

SUPER RUNNER SERIES GAS FRYERS

CHAPTER 1: INSTALLATION INSTRUCTIONS

1-5

When converting from G20 (or G25) gas to G31 propane (or vice-versa), the following procedures apply:

♦ Burner orifices and pilot orifice MUST be replaced.
♦ Adjust orifice gas pressure to the appropriate value listed in the table on page 1-3 by turning the gas-valve

adjustment screw.

♦ After adjustment, replace the adjustment-screw cover.
♦ Affix the new label included with the conversion kit next the existing rating plate stating that the gas type has

been converted. Remove any references to the previously used gas from the existing rating plate.


When converting from G20 (20 mbar) to G25 (25 mbar), or vice-versa, or G31 (37 mbar) to G31 (50 mbar), the
following procedures apply:

♦ Check pilot-adjustment and adjust as necessary.

♦ Other adjustments are not necessary.


Conversion from one gas family to another (i.e. changing from natural gas to propane) requires special components.
Obtain the necessary components using the cross-reference in Section 1.6, Gas Conversion Components.

Conversions can only be executed by qualified, factory-authorized personnel.


NON-CE UNITS ONLY:


See gas valve illustration below and gas valve, burner and orifice location on page 1-6 when performing the following
conversions.

When converting from natural gas to propane (or vice-versa), the following procedures apply:

♦ Burner orifices and pilot orifice MUST be replaced (see page 1-6 for required component part numbers).
♦ Adjust orifice gas pressure by turning the gas-valve adjustment screw (see page 1-3 for gas types and

pressures).

♦ After adjustment, replace the adjustment-screw cover.
♦ Affix the new label included with the conversion kit next the existing rating plate stating that the gas type has

been converted. Remove any references to the previously used gas from the existing rating plate.


Conversion from one gas family to another (i.e. changing from natural gas to propane) requires special components.
Obtain the necessary components using the table on page 1-6.

Conversions can only be executed by qualified, factory-authorized personnel.

Typical Non-CE Gas Valve

ON Button

(pilot gas flow)

OFF Button

Pressure Flow

Adjustment

Thermocouple

Connection

Pilot Flow

Adjustment

Vent tube

connection

ON/PILOT/OFF

Knob

Vent Tube

Connection

Pressure Tap

Typical CE Gas Valve

Advertising
This manual is related to the following products: