First Virtual Communications 065-7710 User Manual

Page 159

Advertising
background image

Signamax

065-7710 8-Port 10/100BaseT/TX + 2SFP Managed Switch

Publication date: January, 2006

Revision A1

151


logout

Syntax:
logout
Description:
When you enter this command via Telnet connection, you would logout the system
and disconnect. If you connect the system through direct serial port with RS-232
cable, you would logout the system and be back to the initial login prompt when you
run this command.
Argument:
None.
Possible value:
None.
Example:
065-7710# logout



restore default

Syntax:
restore default
Description:
When you use this function in CLI, the system will show you the information “Do you
want to restore the default IP address?(y/n)”. If you choose Y or y, the IP address
will restore to default “192.168.1.1”. If you choose N or n, the IP address will keep
the same one that you had saved before.

If restoring default successfully, the CLI would prompt if reboot immediately or not. If
you press Y or y, the system would reboot immediately; otherwise, it would be back
to the CLI system. After restoring default configuration, all the changes in the startup
configuration would be lost. After rebooting, the entire startup configuration would
reset to factory default.

Argument:
None.
Possible value:
None.
Example:
065-7710# restore default
Do you want to restore the default ip address?(y/n)
Restoring ...
Restore default configuration successfully.
Do you want to reboot the system?(y/n)