Optional gas line installation – FMI COMFORT FLAME B42LI-M User Manual

Page 13

Advertising
background image

www.fmiproducts.com

115386-01D

13

opTional gaS line inSTallaTion

Figure 21 - Gas Line Knockout

Side
Firebrick
Finished
Side

Refractory
Knockout
Plug

Outside of
Fireplace

Gas Line
Conduit

Insulation

Gas
Conduit
Cover

1/2" Dowel

Gas line hook up should be done by your
supplier or a qualified service person.
Note: Before you proceed, make sure your
gas supply is turned off.
Use only a 1/2" black iron pipe and appropri-
ate fittings.
1. Remove knockout indentation on refracto-

ry or firebrick wall located above refractory
hearth floor. Knockout indentation must
be firmly tapped with any solid object,
such as a 1/2" dowel, until it is released.
Remove fragmented portions of refractory
(see Figure 21).

2. Remove gas line cover plate located on

either side of fireplace and pull out insu-
lation from gas line conduit sleeve. Save
insulation for reuse.

3. Run a 1/2" black iron gas line into fire-

place through rear at gas line conduit
sleeve (if using a raised platform, add
height). Provide sufficient gas line into
fireplace chamber for fitting connection
(see Figure 22).

Note: Secure incoming gas line to wood
framing to provide rigidity for threaded
end.

4. Repack insulation around gas line and into

sleeve opening. Seal any gaps between
gas line and refractory knockout hole with
refractory cement or commercial furnace
cement. Install gas appliance or cap off
gas line if desired.

CAUTION: All gas piping and

connections must be tested for

leaks after installation is com-

pleted. After ensuring that gas

valve is on, apply soap and water

solution to all connections and

joints. Bubbles forming show a

leak. Correct all leaks at once.

DO NOT USE AN OPEN FLAME

FOR LEAK TESTING AND DO

NOT OPERATE ANY APPLIANCE

IF A LEAK IS DETECTED. LEAK

TESTING SHOULD BE DONE

BY A QUALIFIED SERVICE

PERSON.

Note: A FMI PRODUCTS, LLC hood must be
installed when using an unvented gas log set
(see Accessories on page 18).

WARNING: Do not operate an

unvented gas log set in this fire-

place with chimney removed.

If you install a decorative gas appliance (vent-
ed gas log), decorative gas appliance must
comply with the Standard for Decorative Gas
Appliance for Installation in Solid Fuel Burning
Fireplaces, ANS Z21.60, Z21.84 or RG 2-72

and shall also be installed in accordance with
the National Fuel Gas Code, ANSI 7223NFPA
54 latest edition
.

WARNING: To avoid the risk

of damaging fireplace materials

and increasing the risk of spread-

ing a fire, do not use fireplace to

cook or warm food.

Seal
Opening
with
Refractory
Cement

Outside of
Fireplace

Gas
Line
Conduit

Repack
Insulation

Incoming
1/2" Black
Iron Pipe

Side
Firebrick
Finished
Side

Provide Enough Threaded
End for Fitting Connection

Figure 22 - Gas Line Installation

Advertising