iNsTallaTioN

Continued

We recommend that you install a sediment
trap in supply line as shown in Figure 14, page
13. Locate sediment trap where it is within
reach for cleaning. Install in piping system
between fuel supply and heater. Locate sedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture and
contaminants. This keeps them from going
into fireplace controls. If sediment trap is not
installed or is installed wrong, fireplace may
not run properly.

CONNECTING EqUIPMENT
SHUTOFF VALVE TO HEATER
CONTROL

Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not

provided)

1. Open lower louver (see Figure 15).

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas line

is provided to allow accessibility

from the fireplace (see Figure 14).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

2. Route flexible gas line, included, from

fireplace control to equipment shutoff
valve through side access holes in outer
casing.

3. Apply pipe joint sealant lightly to male

threads of gas connector attached to
flexible gas line/equipment shutoff valve
(see Figure 16).

CAUTION: Avoid damage to

gas control. Hold gas control

with wrench when connecting it

to gas piping and/or fittings

4. Check all gas connections for leaks. See

Checking Gas Connections, below. Feed
flexible gas line into fireplace. Make sure
the entire flexible gas line is in fireplace.

Figure 15 - Flexible Gas Line Location

(Remote-Ready Unit Shown)

Lower
Louver

Flexible Gas
Line

Figure 16 - Attaching Flexible Gas Line

to Equipment Shutoff Valve

Flexible Gas Line
from Fireplace
Gas Regulator
Provided With
Fireplace

To Control Valve

Equipment
Shutoff
Valve

PROPANE/LP

To External Regulator

NATURAL GAS

To Gas Supply

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping

and connections, internal and

external to unit, for leaks after

installing or servicing. Correct

all leaks at once.

WARNING: Never use an

open flame to check for a leak.

Apply a noncorrosive leak detec-

tion fluid to all joints. bubbles

forming show a leak. Correct all

leaks at once.