Installation – FMI COMFORT FLAME CDCFPRB User Manual

Page 15

Advertising
background image

www.fmiproducts.com

124979-01C

15

iNsTallaTioN

Continued

CAUTION: Make sure exter-

nal regulator has been installed

between propane/LP supply and

fireplace. See guidelines under

Connecting to Gas Supply,

page 13.

PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect appliance with its appliance

main gas valve (control valve) and equip-
ment shutoff valve from gas supply piping
system. Pressures in excess of 1/2 psig
will damage heater regulator.

2. Cap off open end of gas pipe where equip-

ment shutoff valve was connected.

3. Pressurize supply piping system by either

opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas or using compressed air.

4. Check all joints of gas supply piping sys-

tem. Apply noncorrosive leak detection
fluid to all joints. Bubbles forming show a
leak.

5. Correct all leaks at once.
6. Reconnect fireplace and equipment

shutoff valve to gas supply. Check recon-
nected fittings for leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Fig-

ure 17).

2. Pressurize supply piping system by either

opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas or using compressed air.

3. Check all joints from gas meter to equip-

ment shutoff valve for natural gas or pro-

pane/LP supply to equipment shutoff valve
for propane/LP (see Figures 18 or 19).
Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.

4. Correct all leaks at once.

PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Fig-

ure 17).

2. Open main gas valve located on or near

gas meter for natural gas or open pro-
pane/LP supply tank valve.

3. Make sure control knob of fireplace is in

the OFF position.

4. Check all joints from equipment shutoff valve

to control valve (see Figures 18 or 19). Apply
noncorrosive leak detection fluid to all joints.
Bubbles forming show a leak.

5. Correct all leaks at once.
6. Light fireplace (see Operation, page 18).

Check all other internal joints for leaks.

7. Turn off fireplace (see To Turn Off Gas to

Appliance, page 19.

Figure 18 - Checking Gas Joints

(Propane/LP Only)

Propane/
LP Supply
Tank

Equipment
Shutoff
Valve

Equipment
Shutoff Valve

Gas Meter

Figure 19 - Checking Gas Joints

(Natural Gas Only)

Gas Control Valve

Figure 17 - Equipment Shutoff Valve

Open

Closed

Equipment
Shutoff
Valve

Gas Control Valve

Advertising
This manual is related to the following products: