Installation – FMI COMFORT FLAME CDCFPRB User Manual

Page 16

Advertising
background image

www.fmiproducts.com

124979-01C

16

OPTIONAL WALL MOUNTED
THERMOSTAT - GWMT1

WARNING: Read and fol-

low installation instructions.

Installation should be done by

a qualified installer familiar with

low-voltage wiring procedures.

WARNING: Do not connect

this thermostat to any electrical

source! Electrical shock and/or

fire hazard will occur.

1. Remove jumper wire from control valve

(see Figure 20).

2. Connect one terminal of 25 ft. wire to

the “TH” terminal on the control valve.
Connect the other terminal to the “THTP”
terminal on the control valve. See Figure
22.

3. Route the 25 ft. wire to a convenient loca-

tion to mount your thermostat (no outside
wall). IMPORTANT: The wire may be
shortened but must not be lengthened.

The thermostat should be mounted 54"
above the floor in a location where there
is good air circulation. Avoid heat sources
such as lamps, direct sunlight, fireplace
or heat and air conditioning ducts.

4. Gently remove cover of thermostat from

base. Grasp sides of cover firmly and pull
to separate from base.

5. Feed electrical wires through rectangular

slots on each side of base (see Figure 23).

iNsTallaTioN

Continued

Figure 23 - Back View of Thermostat Base

Feed wires through
rectangular slots

W

R

Figure 24 - Thermostat Base Terminals

“W” and “R”

Terminal “W”

Terminal “R”

Figure 22 - Connecting Wire Terminals

To Wall
Thermostat
or Switch

To Wall
Thermostat
or Switch

Control Valve

WARNING: Do not con-

nect the thermostat to a power

source. Electrical shock and/or

a fire hazard will occur.

6. Connect one bare wire end to each termi-

nal (“W” and “R”) of the thermostat base
(see Figure 24).

7. Install base onto wall with provided

screws.

Figure 20 - Disconnecting Jumper Wires

From Control Valve