Arpa functions, Interfacing, Power supply – Furuno FR-2805 Series User Manual

Page 12

Advertising
background image

x

5. Bearing accuracy

±

1

°

6. Bearing discrimination

Better than 2.5

°

except S-band 10 ft radiators

(SN-30AF)

7. Presentation modes

Head-up, Head-up TB, North-up, Course-up,
True motion north-up
(Automatically set to HU in case of compass
failure)

8. Variable Range Markers

Two Variable Range Markers, switched

9. Electronic Bearing Lines

Two Electronic Bearing Lines, switched
Range merker on EBL

10. Offcenter

IMO type: Sweep origin can be offcentered
by 75% of range in use in any direction.
Regular type: Any direction up to 100%

11. Target alarm zone

2 TAZ at 3 and 6 nm in width of 0.5 nm, any
sector.

12. Electronic plotting (E-plot)

10 targets manual plotting. Not operative in
ARPA mode.

13. Parallel index lines

2, 3 and 6 lines (selectable on menu)

14. Navigation lines (option)

Two lines to define a navigation channel
(with RP-25)

ARPA FUNCTIONS

1. Acquisition

Instant selection of auto or manual acquisition
in 0.2 to 32 nm, relative speed 100 kt. Auto
20 targets plus manual 20 targets, or Manual
40 targets

2. Tracking

Automatic tracking of all acquired targets on
the display for 5 out of 10 consecutive scans
in 0.1 to 32 nm

3. Prediction of target motion

True or relative vectors, time scaled.
Length: 1 to 99 min

4. Past positions

5 or 10 past positions of tracked targets at
intervals of 2 min

5. Collision warning

CPA limit: 0.2 to 10 nm
TCPA limit: 0 to 99 min

6. Guard zone (Guard ring)

2 guard zones (guard rings) of operator-
defined width in 0.7 to 32 nm, Sector 1 to
360

°

any direction

7. Trial maneuver

Simulates the effect on all tracked targets of
own ship maneuver with course, speed and
delay time.

INTERFACING

1. IEC 61162-1

OSD, RSD, TTM, etc. (Listener 2 mA at 2V,
Talker 60 mA max)

2. Analog

RGB video, H/V sync for VDR with optional
board)

3.Gyrocompass

Built-in interface accepts synchro signal (20-
50 V, 50-400 Hz) or stepper signal (20-50
VDC, any polarity).

4. Speed log (IEC 61192-1 interface)

IEC 61192-1 contact closure or 200/400/500
pulses/nm.

POWER SUPPLY

1. FR/FAR-2815/2825

115/230 VAC, 1ø, 470 VA(2815), 500
VA(2825), DC set not available

2. FR/FAR-2825W/2855/2855W

Display unit: 115/230 VAC, 1ø, 500 VA
(2825W), 115 VAC, 1ø, 550 VA (2855/
2855W)
Antenna unit: 115/230 VAC, 1ø, 150 VA
(2825W/2855W), 230 VAC, 3ø, 120 VA, 380/
440 VAC, 3ø, 120 VA (2825W/2855W), 24 V,
30 W (2855)

3. FR/FAR-2835S/2835SW

Display unit: 115/230 VAC, 1ø, 500 W
Antenna unit: 220 VAC, 50-60 Hz, 3ø,
440 VA, 380/440 VAC, 50-60 Hz, 3ø, 440 VA

4. FR/FAR-2865SW

Display unit: 115 VAC, 1ø, 550 VA
Antenna unit: 220 VAC, 3ø, 50-60 Hz, 440
VA, 380/440 VAC, 3ø, 50-60 Hz, 440 VA

Advertising