1-20

2. Press the OFF CENTER key. Then, the

sweep origin is off-centered to the cur-
sor position.

3. To cancel off-centering, press the OFF

CENTER key again.

HL

OFF

ECHO

TRAILS

MODE

ORIGIN

MARK

VECTOR

TRUE/

REL

VECTOR

TIME

GUARD

ALARM

EBL

OFFSET

OFF

CENTER

Inside mode panel

Cursor

Cursor

Off-centered to cursor position – Max.
offset
100% of range in use on R-type
75% of range in use on IMO-type

The picture cannot be off centered in
the true motion mode.

1.22 Echo Stretch

On long ranges target echoes tend to
shrink in the bearing direction, making
them difficult to see. On short and me-
dium ranges such as 1.5, 3 and 6 nm
scales, the same size targets get smaller
on screen as they approach the own ship.
These are due to the inherent property of
the radiation pattern produced by the an-
tenna. To enhance target video, use the
echo stretch function. There are two
types: echo stretch 1 for long range de-
tection and echo stretch 2 on 1.5-6 nm
scales.

To activate the echo stretch:

1. Press the RADAR MENU key on the

plotting keypad to show the FUNC-
TIONS menu.

2. Press the [2] key to select 2 ECHO

STRETCH.

3. Press [2] until Echo Stretch option 1, 2

or OFF as desired is highlighted.

4. Press the ENTER key to conclude your

selection followed by the RADAR
MENU key to close the FUNCTIONS
menu.

Hit [RADAR MENU].

* R-type only


1 PULSE WIDTH
2 ECHO STRETCH
3 ECHO AVERAGE
4 PANEL DIMMER
5 ECHO COLOR
6 SHIP'S SPEED
7 INDEX LINES
8 SET/DRIFT

9 BRILLIANCE
0 [SYSTEM SETTING 1]

1/2
OFF/1/2
OFF/1/2/3
OFF/DIM/M/BRT
YEL/GRN/COLOR*
LOG/NAV*/MAN
NO.2 VRM/MAN
OFF/MAN
SET 000.0
DRIFT 00.0 KT

[FUNCTIONS 1]

(a) Echo stretch 1 for 12 nm range
and above

Enlarged in bearing
(circumferential)
direction with ES1

(b) Echo stretch 2 for 1.5–6 nm ranges

Enlarged with
ES2

If a distant target
is hard to see, use
ES 1.

If a target becomes
smaller as it
approaches own
ship, use ES 2.

Notes:

1) If the 1.5 nm range is preset for

pulsewidth of S1 (0.08

µ

s) or S2 (0.2

µ

s), and the 3 nm scale for S2 (0.2

µ

s),

the echo stretch function is not avail-
able on these range scales.

Advertising