Furuno FR-2805 Series User Manual

Page 67

Advertising
background image

2-6

To set auto acquisition areas with
trackball

To set auto acquisition areas with
trackball:

1. Press the E, AUTO PLOT MENU key

to show the ARPA 1 menu.

2. Press the [2] key to select menu item

2AUT O ACQ AREA.

3. Further press the [2] key to select (or

highlight) SET option.

4. Press the ENTER key to conclude your

selection. At this point the AUTO ACQ
SETTING menu is displayed at the
screen bottom.

[AUTO ACQ SETTING]

1 [AUTO PLOT 1]
2 1/2

5. Press the [2] key to select menu item

21/2 and press the ENTER key . Then,
you will see the message as shown
below:

[AUTO ACQ SETTING]

1 [AUTO PLOT 1]
2 1/2

SET LEFT/RIGHT BOUNDARY
CANCEL PREVIOUS AREA: CANCEL KEY

6. Place the cursor at the outer counter-

clockwise corner of the area (point A)
and press the ENTER key.

7. Place the cursor at the clockwise edge

of the area (point B) and press the
ENTER key.

A

B

0.5 nm

Automatic acquisition area set by

trackball

Note: If you wish to create an auto
acquisition area having a 360-degree
coverage around own ship, set point B
in almost the same direction (approx.

±

3

°

) as point A and press the ENTER

key.

8. Repeat steps 5 to 7 above if you want

to set another auto acquisition area with
the trackball.

9. Press the [1] key followed by the E,

AUTO PLOT MENU key to close the
ARPA 1 menu.

An auto acquisition area like the example
shown above appears on the display.
Note that each auto acquisition area has
a fixed radial extension (width) of 0.5 nm.

Note that the auto acquisition areas are
preserved in an internal memory of the
ARPA even when auto acquisition is dis-
abled or the ARPA is turned off.

Terminating tracking of targets

When the ARPA has acquired 20 targets
automatically, the message AUTO TAR-
GET FULL is displayed in the box at right-
hand side of the screen and no more auto
acquisition occurs unless targets are lost.
You may find this message before you set
an auto acquisition area. Should this hap-
pen, cancel tracking of less important tar-
gets or perform manual acquisition.

Individual targets

Place the cursor (+) on a target to cancel
tracking by operating the trackball. Press
the CANCEL key.

All targets

Press and hold the CANCEL key down
more than 3 seconds. In the automatic
acquisition mode, acquisition begins
again.

Discrimination between
landmass and true targets

A target is recognized as a landmass and
thus not acquired if it is 800 m or more in
range or bearing direction.

Advertising
This manual is related to the following products: