Furuno FR-2805 Series User Manual

Page 97

Advertising
background image

A-3

A.3 Navigation Data (IEC 61162-1 Edition 1 and Edition2)

1. I/O Sentences for Channel 1

Input

BWC, BWR, DBT, DPT, GGA, GLL, MTW, MWV, RMA, RMB, RMC, VDR, VTG(*),
ZDA

*: not recommended in IMO-type

2. I/O Sentences of Channel 2

Input

VBW, VHW, HDT

Output

RAOSD, RARSD (An interval of three seconds)

3. I/O Sentences of Channel 3

Output

RATTM (Every five seconds when acquiring 10 targets)

4. Sentence Description

See pages which follow.

Note: Checksum for RMA, RMB, and RMC is mandatory. Checksum for other sen-
tences is evaluated if it exists.

5. Priority

Nav data sentences below are read left to right, and in case of timeout the sentence
right of last read sentace is read. In case of multiple high priority sentences the sen-
tences having the highest priority is read. ** is read regardless of talker. Timeout is 30
seconds unless specified otherwise. Difficult time-outs for data sentences are required
by German authorities.

Position data

GPGGA>GPRMC>GPGLL>LCRMA>LCGLL>**GLL

Timeout: 30 seconds

Advertising