App lic ati on s eri es g as fr ye rs, Frymaster – Frymaster HD60G User Manual

Page 2

Advertising
background image

Frymaster

®

A

pp

lic

ati

on

S

eri

es

G

as

Fr

ye

rs

M

o

d

el

#_

__

__

__

__

__

__

__

C

SI

Se

ct

io

n

1

14

00

8700 Line Avenue

Shreveport, LA 71106-6800

USA

Tel: 318-865-1711

Tel: 1-800-221-4583

Fax: 318-868-5987

E-mail: [email protected]

www.frymaster.com

Bulletin No. 818-0491 9/07

Litho in U.S.A. ©Frymaster, LLC

moDel no.

overAll SIze (mm)

net

weIght

DrAIn

heIght

ShIPPIng InformAtIon

heIght

wIDth

length

weIght

ClASS

Cu. ft.

DImenSIonS

DF400

H255-D260

45”

(1143)

71.25”

(1810)

36.5”

(927)

942 lbs.

(427 kg)

13”

(330)

1,000 lbs.

(373 kg)

77.5

109.5

H

55”

(1397)

W

80”

(2032)

L

43”

(1092)

diMenSiOnS

pOwer requireMentS

hOw tO SpeciFy

DF400 H255-D260 Free-standing gas fryers with computer controls, under fryer

built-in oil filtration, stainless steel frypots, doors and cabinet.

nOteS

Supply Voltage 120V 60 Hz -- Control Voltage 24V 60
Hz.
120 VAC 5 ft. (1.5 m) grounded cord set provided.
Recommended minimum store supply pressure to be
6” W.C. for NAT Gas, and 11” W.C. for L.P. Check plumb-
ing codes for proper supply line sizing to attain burner
manifold pressure of 3.0” W.C. natural or 8.25” W.C. L.P.
Incoming supply line should be 1-1/2”. Should flexible
gas line be used, it must be AGA approved, commercial
type and sized per the gas line size in above drawing.

cLeArAnce inFOrMAtiOn

A minimum of 24” (610 mm) should be provided at the
front of the unit for servicing and proper operation,
and 6” (152 mm) between the sides and rear of the fryer
to any combustible material.

31.25

[794]

71.25

[1810]

INCHES

MM

36.50

[927]

45.75

[1162]

CONTROL

PANEL

FRONT VIEW

TOP VIEW

SIDE VIEW

1" GAS CONNECTION

80,000 BTU (PER EACH H55)

CORDSET

CORDSET

1" GAS CONNECTION

150,000 BTU (PER EACH D60)

36.50

[927]

CORDSETS

DOWN SPOUT

GAS CONNECTIONS

CORDSET

11.25

[286]

moDel

no.

nAturAl or lP gAS

InPut rAtIng

eleCtrICAl

gAS

ConneCtIon

H55

80,000 BTU/hr. input

(20,151 kCal) (23.4 kW)

Non-basket lift

120V (1.0 AMP)
220V (0.5 AMP)

Basket Lift

120V (7.0 AMP)
220V (3.5 AMP)

1” N.P.T.

regulator not

required

H55-2

D60

150,000 BTU/hr. input

(37,783 kCal/hr.) (44 kW)

120V/60

~1ø (3.5 AMP)

230V/50

~1ø (2 AMP)

1” N.P.T.

regulator not

required

85UFF

N/A

120V/60 Hz/1 ph

(6.2 AMP)

N/A

We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.

moDel

mAx oIl

CAPACIty

(lIterS)

SIze (Cm)

APProxImAte

weIght

wIDth

DePth

heIght

85UFF

85 lbs. (42)

16.12” (41)

29.63”

(75.26)

10.25”

(26)

210 lbs. (95)

Model Shown is DF400 H255-D260

Other combinations are available.

Advertising
This manual is related to the following products: