6 command phase, 7 data phase – FUJITSU MCP3130SS User Manual

Page 135

Advertising
background image

7.6 Bus Phases

C156-E228-02EN 7-33

7.6.6 COMMAND phase

The COMMAND phase is a bus phase in which the TARG requests the INIT to
transfer command information (CDB) to the TARG. The TARG keeps the C/D
signal true and the I/O and MSG signals false during REQ/ACK handshaking in
this phase.

7.6.7 DATA phase

The DATA phase is divided into DATA IN and DATA OUT phases according to
the direction of data transfer. In a DATA phase, synchronous data transfer can be
performed.

(1) DATA IN phase

In a DATA IN phase, the TARG requests to transfer data from the TARG to the
INIT. The TARG keeps the I/O signal true and the C/D and MSG signals false
during REQ/ACK handshaking in this phase.

(2) DATA OUT phase

In a DATA OUT phase, the TARG requests to transfer data from the INIT to the
TARG. The TARG keeps the C/D, I/O, and MSG signals false during REQ/ACK
handshaking in this phase.

(3) Data transfer rate in asynchronous mode

Figure 7.16 shows the REQ/ACK handshake timing that the ODD observes in a
DATA phase where asynchronous transfer is used. The data transfer rate on the
SCSI bus depends on sum of the ACK response time in the INIT and the signal
delay time of the interface cable (T1 and T2 in Figure 7.16).

Advertising