Setting example 3 (bad example) – FUJITSU fi-6130 User Manual

Page 191

Advertising
background image

Unit: mm

HINT

When [Check Overrapping(Ultrasonic)] is selected, the multifeed detection ratio may drop if

the document sheet(s) are glued or electrostatically adhered to each other.

Setting Example 3 (Bad Example)

Selected range=Enable, Start=100mm, End=102mm

Unit: mm

* Since the detection range (length) is less than the minimum value (5 mm), the Multifeed Detection cannot be performed

correctly.