Operating tips, En-18, Temperature and humidity range – Friedrich MW12C3E User Manual

Page 21

Advertising
background image

En-18

OPERATING TIPS

Indoor temperature

Outdoor temperature

Indoor humidity

Cooling and Dry Mode

95 °F DB / 71 °F WB

64 °F DB / 55 °F WB

115 °F DB

32 °F DB

About 80 % or less

If the unit is used for long periods under high-humidity conditions, condensation
may form on the surface of the indoor unit, and drip onto the floor or other objects
underneath.

About 50 % or less

If the unit is used for long periods under high-humidity conditions, condensation
may form on the surface of the indoor unit, and drip onto the floor or other objects
underneath.

Temperature and Humidity Range

DB : Dry Bulb Temperature
WB : Wet Bulb Temperature

● If the air conditioner is used under higher temperature conditions than those listed, the built-in protection circuit may

operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of
lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.

● Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary

dwellings.

Maximum

Minimum

Maximum

Minimum

Outdoor
Temperature
68 °F or above

Outdoor
Temperature
below 68 °F