Furuno NX-700B User Manual

Page 52

Advertising
background image

4. INSTALLATION

4-6

Receiver unit

All cables are gathered to the receiver unit. Connect cables at inside of the
receiver unit as shown below.

DSUB25P-DSUB25P-3M cable
(to Display unit)

DPYC-2.5

(to ship's battery)

RCV Board
08P3227

TTYCS-1Q
(to Navigator
or INS )

DPYC-1.5
(to External alarm)

Printer cable
(to Printer, NX-700B only)

Antenna cable
(to Antenna unit)

TB401

(+)

TB402
(-)

J402*

J403

J401

1 2 3 4 5 6

1 2 3 4 5 6 7 8

Receiver unit, inside view

Use the following JIS cable (Japan Industrial Standard) or equivalent to connect
power source, INS and external alarm appropriately.

Conductor

S = 2.5 mm

φ

= 2.01 mm

2

DPYC-2.5

Armor

Sheath

φ

=

12.5 mm

Conductor

S = 1.5 mm

φ

= 1.56 mm

2

DPYC-1.5

Armor

Sheath

φ

=

11.7 mm

Conductor

S = 0.75 mm

φ

= 1.11 mm

2

TTYCS-1Q (Four core twisted)

Armor

Shield

Sheath

φ

=

11.3 mm


For printer, use the cable supplied with the printer.

Advertising