Furuno NX-700B User Manual

Page 54

Advertising
background image

4. INSTALLATION

4-8


Antenna cable

Be sure to leave some slack in the cable for future service and maintenance.

For RG-10/UY, RG-214 cable
When using the coaxial cable, type RG-10/UY or RG-214, attach the FM-MP-7
connector (supplied as installation material) or PL-259 (local supply) as below.

1. Remove the sheath by 30 mm.
2. Bare 23 mm of the center conductor. Trim braided shield by 5 mm and tin.
3. Slide coupling ring onto cable.
4. Screw the plug assembly on the cable.
5. Solder plug assembly to braided shield through solder holes. Solder contact

sleeve to conductor.

6. Screw coupling ring into plug assembly.

Sheath

30 mm

5 mm

2 mm

Conductor

Insulator

Braided shield

Plug assembly

Contact sleeve

Cut conductor here.

Solder both
sides of hole.

Coupling ring

Solder here.

Note: When the RG-214 cable is used, care must be exercised to prevent

damage to the cable as it has no armor.

Advertising