Specifications, Furuno, Antenna radiators – Furuno BB FAR28x7 User Manual

Page 23: Rf transceiver, Sp - 1

Advertising
background image

FURUNO

FAR-21x7(-BB)/28x7 SERIES

SP - 1

E3519S01L-M

SPECIFICATIONS OF MARINE RADAR/ARPA

FAR-21x7(-BB)/28x7 SERIES

1. ANTENNA RADIATORS

1. Type

Slotted waveguide array

2. Beam width and sidelobe attenuation

X-band S-band

Radiator type

XN4A XN5A

XN12AF XN20AF

XN24AF SN30AF SN36AF

Length

8 ft

10 ft

4 ft

6.5 ft

8 ft

10 ft

12 ft

Beam width(H)

0.95°

0.75°

1.8°

1.23°

0.95°

2.3°

1.8°

Beam width(V)

20°

20° 20° 20° 20° 25° 25°

Sidelobe within ±10°

-28 db

-26 db

-24 db

-28db

-28 db

-24 db

-24 db

Sidelobe outside ±10°

-32 db

-30 db

-30 db

-32 db

-32 db

-30 db

-30 db

3. Polarization

Horizontal

4. Rotation

FAR-2117/2117-BB/2127/2127-BB/2827: 24 rpm or 42 rpm
FAR-2157/2157-BB: RSB-106, 18 rpm (50 Hz)/22 rpm (60 Hz),

RSB-107, 22 rpm

FAR-2137S/2137S-BB/2837S: 21 rpm (50 Hz)/26 rpm (60 Hz)/

45 rpm (HSC)

FAR-2167DS/2167DS-BB/2837SW: 21 rpm (50 Hz)/26 rpm (60 Hz)

FAR-2827W: 24 rpm

5. De-icer (option)

On: When temperature goes down to +5°C

Off: When temperature goes up to +12°C

2. RF TRANSCEIVER

1. Frequency

X-band: 9410 MHz ±30 MHz, S-band: 3050 MHz ±30 MHz

2. Output power

FAR-2117/2117-BB/2817: 12 kW
FAR-2127/2127-BB/2827/2827W: 25 kW
FAR-2137S/2137S-BB/2837S/2837SW: 30 kW
FAR-2157/2157-BB: 50 kW
FAR-2167DS/2167DS-BB: 60 kW
Unwanted emissions comply with ITU-R RR.

3. Pulselength, PL, PRF and range

X- band 12 kW and 25 kW models

Pulselength S1 S2 M1 M2 M3 L
PL

(µs)

0.07 0.15 0.3 0.5 0.7 1.2

PRF (Hz)

3000*

3000*

1500

1000

1000

600**

Range scale
(nm)

0.125,
0.25, 0.5,
0.75, 1

#

,

1.5, 2

#

0.5, 0.75,
1

#

, 1.5, 2

#

,

3, 4

#

0.75, 1

#

,

1.5, 2

#

, 3,

4

#

, 6, 8

#

3, 4

#

, 6,

8

#

, 12,

16

#

, 24

3, 4

#

, 6,

8

#

, 12,

16

#

, 24

6, 8

#

, 12,

16

#

, 24,

32

#

, 48,

96, 120

#

*: 2200 Hz with ARPA on, 32 nm range **: 500 Hz on 96 and 120 nm ranges #: Non-IMO type only
X- band 50 kW and S-band 60 kW models

Pulselength S M1 M2 L
PL (µs)

0.08

0.2

0.6

1.2

PRF (Hz)

1900

1100

600

600**

Range scale
(nm)

0.125,
0.25, 0.5,
0.75, 1,
1.5, 2

0.75, 1,
1.5, 2, 3, 4

3, 4, 6, 8,
12, 16, 24

6, 8, 12,
16, 24, 32,
48, 96,
120

**: 500 Hz on 96 and 120 nm ranges

4. IF

60 MHz

5. Noise figure

6 dB (typical)

Advertising