Danger, Extreme – Frymaster Super Cascade Filtration Systems CE User Manual

Page 11

Advertising
background image

9

Plug is in the bottom of the

filter pan or in the line from the

filter to the pump.

Disconnect the tubing from

the filter pan to the motor.

Make sure the pipe is cool.

The line is clear.

Reconnect hose to the

pump inlet.

Can you blow air

through it?

Yes

No

The line is clogged.

Run a cable through the

line to clear clogs.

Continue until you can

blow air through it.

Turn pump ON.

Does oil flow?

Conduct normal
filter operations.

Yes

No

There may be a plug in

the oil return line

system.

Disconnect the oil return line

running from the pump to the oil

return valve. Clean the pipe to

remove residual shortening.

Disconnect the oil return line

running from the oil return valve

to the frypot. Clean the pipe to

remove residual shortening.

Reconnect the oil

return lines.

Turn pump ON.

Does oil flow?

Conduct normal

filter operations.

Yes

No

Contact your

Factory

Authorized

Servicer.

Enter from

page 8 here.

DANGER!

NEVER USE A PROPANE TORCH
TO MELT SOLIDIFIED
SHORTHENING IN ANY PART OF
THE SYSTEM. YOU WOULD BE
USING AN OPEN FLAME NEAR
COMBUSTIBLES. THE FIRE
HAZARD IS

EXTREME!

Advertising