3

Hold down ring latched into position.

24G Drain
Hole

H250 Drain

Hole

Filter Pan Lid Drain Holes

f. Unlatch and remove the hold down ring.

Remove and discard old filter paper sheet from
the filter pan.

g. Clean out the filter pan.

h. Place one sheet of filter paper in the bottom of

the filter pan. Reinstall and latch the hold down
ring into position.

i. Sprinkle 8 ounces (1 cup)/ 227 grams evenly

over the paper. Return cover to the filter pan.

j. Return filter pan to fryer cabinet, making sure

the two drain pipe extensions are directly over openings in filter pan cover.

k. Ensure the oil pickup tube fits snugly in the

filter pan connector.

4. FILTER OPERATIONS:

a. Flatbottom 24G:

1. Stir the oil in the frypot with the L-shaped teflon brush.

2. Open the flatbottom frypot drain valve by turning the large red drain handle from the 9:00

o'clock position to the 6:00 o'clock position.

3. Continue stirring the oil in the frypot with the L-shaped teflon brush as the oil drains into the

filter pan. Brush down the vessel sides to remove debris. Use the clean-out rod to clear the
drain if necessary.

Oil Pickup Tube

CAUTION

Filter one frypot at a time. The filter
pan is designed to safely hold the oil
from one fryer only.

SCF99 ready for operation.