Filter troubleshooting – Frymaster Super Cascade Filtration Systems CE User Manual

Page 8

Advertising
background image

6

5. FILTER TROUBLESHOOTING:

The problems and possible solutions covered are those most commonly encountered.

To troubleshoot, perform the test set-up at the beginning of each condition. Start at the top of the
diagram. Arrows direct the troubleshooter through the sequence. Follow each step in sequence as
shown in the troubleshooting diagrams.

Troubleshooting Diagram Index

Section

Problem

Page

5.1

Super Cascade filter pump fails to pump oil?

6

5.2

Rate of oil return slowing?

7

5.3

Blockage between filter pan and oil return valve?

8

5.1 SUPER CASCADE FILTER PUMP FAILS TO PUMP OIL?

WARNINGS!

INSPECTION, TESTING, AND REPAIR OF GAS OR ELECTRICAL
EQUIPMENT SHOULD BE PERFORMED BY QUALIFIED PERSONNEL.

USE EXTREME CARE DURING ELECTRICAL CIRCUIT TESTS. LIVE
CIRCUIT WILL BE EXPOSED.

Reset filter circuit

breaker and wall circuit

breaker (if necessary).

Filter pump

fails to pump

oil.

Turn pump motor

ON by turning the

oil return handle.

Does oil flow?

Conduct

normal filter

operations.

Is the pump

motor running?

Yes

No

There may be

blockages in the

oil lines.

Contact your

Frymaster

Servicer.

Go to page 7 and
follow procedures

for Rate of Oil

Return Slowing.

No

Yes