6. WIRING DIAGRAM (Super Cascade Filter (CE), 230VAC/50Hz)

Block

810-0164

Power Cord

807-1697

230 VAC

24 VAC

Connection from

Fryer

SCF24MCD Oil Return

Transformer/Relay

Assy

Relay

24V DPDT

501-0058

Add-on RH

Fryer Relay

24V DPDT

501-0058

Add-on LH Fryer

Relay

24V DPDT

501-0058

Oil Return Micro

Switch (Polishing

Valve)

501-0111

Oil Return Micro

Switch Connection

Add-on Fryers

Male Push-on Pins

807-1397

Shown in OFF

Position

Pump Motor (5D)

501-0087

Motor

For change of rotation,

interchange leads T5 and

T8 on the motor.

Circuit Breaker

5 AMP

Amp

Connector

Oil Return Micro

Switch

501-0111

Add-on from LH

Fryer when

used.

91.44 cm/36 inch long leads

33.02 cm/13 inch

long leads

RED

20.32 cm/8 inch long leads

WHT

RED

WHT

WHT

RED

WHT

WHT

WHT

WHT

YEL

PUR

PUR

WHT

YEL

YEL

YEL#1

YEL#1

YEL#1

PUR

RED

BLU

BLK

BLU

RED

BLK

YEL

ORG

BLK

ORG

ORG

BLK

BLK

ORG

BLK

BLK

WHT#2

WHT

BLU

BLU

WHT

WHT#2

WHT#2

ORG

BLK

BLK

WHT#1

BLK

WHT#1

BLK

T1

T2

T3

T5

T4

T8

GRN

WHT

BLU

NC

NO

COM

NC

NO

COM

NC

NO

COM

24V

24V

NC

NO

COM

NC

NO

COM

24V

230V Filter Circuit

230V Filter Circuit

CB

2

2
1

1

2
1

2
1

1

T1 T2

2

3

4