NORMAL FUNCTION OF VALVE

VALVE

OPERATING

CONDITION

DISCH

A

R

G

E

TU

BE

fro

m

Co

m

p

re

sso

r

S

U

CT

IO

N T

U

B

E

t

o

Co

m

p

re

ss

o

r

Tu

b

e

t

o

I

N

S

ID

E

COI

L

Tu

b

e

t

o

O

U

T

S

ID

E

COI

L

LEF

T

Pilot

Ca

pi

lla

ry

T

u

be

RIG

H

T

P

ilo

t

Ca

pi

lla

ry

T

u

be

NOTES:

* TEMPERATURE OF VALVE BODY

** WARMER THAN VALVE BODY

1

2

3

4

5

6

POSSIBLE CAUSES

CORRECTIONS

Normal Cooling

Hot

Cool

Cool

as (2)

Hot

as (1)

*TVB

TVB

Normal Heating

Hot

Cool

Hot

as (1)

Cool

as (2)

*TVB

TVB

MALFUNCTION OF VALVE

Valve will not
shift from cool
to heat.

Check Electrical circuit and coil

No voltage to coil.

Repair electrical circuit.

Defective coil.

Replace coil.

Check refrigeration charge

Low charge.

Repair leak, recharge system.

Pressure differential too high.

Recheck system.

Hot

Cool

Cool,

as (2)

Hot,

as (1)

*TVB

Hot

Pilot valve okay. Dirt in one bleeder hole.

De-energize solenoid, raise head pres-
sure, reenergize solenoid to break dirt
loose. If unsuccessful, remove valve, wash
out. Check on air before installing. If no
movement, replace valve, add strainer to
discharge tube, mount valve horizontally.

Piston cup leak

Stop unit. After pressures equalize, restart
with solenoid energized. If valve shifts,
reattempt with compressor running. If still
no shift, replace valve.

Valve will not
shift from cool
to heat.

Hot

Cool

Cool,

as (2)

Hot,

as (1)

*TVB

*TVB

Clogged pilot tubes.

Raise head pressure, operate solenoid to
free. If still no shift, replace valve.

Hot

Cool

Cool,

as (2)

Hot,

as (1)

Hot

Hot

Both ports of pilot open. (Back seat port did
not close).

Raise head pressure, operate solenoid to
free partially clogged port. If still no shift,
replace valve.

Warm

Cool

Cool,

as (2)

Hot,

as (1)

*TVB

Warm

Defective Compressor.

Replace compressor

Starts to shift
but does not
complete
reversal.

Hot

Warm

Warm

Hot

*TVB

Hot

Not enough pressure differential at start of
stroke or not enough fl ow to maintain pres-
sure differential.

Check unit for correct operating pressures
and charge. Raise head pressure. If no
shift, use valve with smaller port.

Body damage.

Replace valve

Hot

Warm

Warm

Hot

Hot

Hot

Both ports of pilot open.

Raise head pressure, operate solenoid.
If no shift, use valve with smaller ports.

Hot

Hot

Hot

Hot

*TVB

Hot

Body damage.

Replace valve

Valve hung up at mid-stroke. Pumping vol-
ume of compressor not suffi cient to maintain
reversal.

Raise head pressure, operate solenoid.
If no shift, use valve with smaller ports.

Hot

Hot

Hot

Hot

Hot

Hot

Both ports of pilot open.

Raise head pressure, operate solenoid.
If no shift, replace valve.

Apparent
leap in heating.

Hot

Cool

Hot,

as (1)

Cool,

as (2)

*TVB

*TVB

Piston needle on end of slide leaking.

Operate valve several times, then recheck.
If excessive leak, replace valve.

Hot

Cool

Hot,

as (1)

Cool,

as (2)

** WVB

** WVB

Pilot needle and piston needle leaking.

Operate valve several times, then recheck.
If excessive leak, replace valve.

Will not shift
from heat to
cool.

Hot

Cool

Hot,

as (1)

Cool,

as (2)

*TVB

*TVB

Pressure differential too high.

Stop unit. Will reverse during equalization
period. Recheck system

Clogged pilot tube.

Raise head pressure, operate solenoid to
free dirt. If still no shift, replace valve.

Hot

Cool

Hot,

as (1)

Cool,

as (2)

Hot

*TVB

Dirt in bleeder hole.

Raise head pressure, operate solenoid.
Remove valve and wash out. Check on
air before reinstalling, if no movement,
replace valve. Add strainer to discharge
tube. Mount valve horizontally.

Hot

Cool

Hot,

as (1)

Cool,

as (2)

Hot

*TVB

Piston cup leak.

Stop unit. After pressures equalize, restart
with solenoid de-energized. If valve shifts,
reattempt with compressor running. If it
still will not reverse while running, replace
the valve.

Hot

Cool

Hot,

as (1)

Cool,

as (2)

Hot

Hot

Defective pilot.

Replace valve.

Warm

Cool

Warm,

as (1)

Cool,

as (2)

Warm

*TVB

Defective compressor.

Replace compressor