ELECTRICAL TROUBLESHOOTING CHART — HEAT PUMP

NO

Is Line Voltage

Present at the Solenoid

NO

YES

YES

TROUBLESHOOTING CHART — HEATING

Noncondensables (air)

Overcharged

Low Airfl ow Across

Indoor Coil

Outdoor Ambient Too High

For Operation In Heating

High Head Pressure

REFRIGERANT SYSTEM DIAGNOSIS – HEATING

Moisture in System

Defective Compressor

Undercharged

Overcharged

Refrigerant System

Restriction

Reversing Valve not

Fully Seated

Low Airfl ow

Across Outdoor Coil

Outdoor Ambient Too High

for Operation in Heating

Low Suction Pressure

High Suction Pressure

Refrigerant System

Restriction

Low Head Pressure

Reversing Valve not

Fully Seated

Undercharged

Defective Compressor

Is the Solenoid Coil Good?

Reversing Valve Stuck

Replace the Reversing Valve

Replace the Solenoid Coil

Is the Selector Switch

Set for Heat?

HEAT PUMP

SYSTEM COOLS WHEN

HEATING IS DESIRED.