Frymaster GF14 User Manual

Page 25

Advertising
background image

4-7

Problem

Probable Cause

Corrective Action

A. Loose, dirty or corroded hi-limit

wires.

A. Clean/tighten hi-limit wires on gas

valve.

Pilot remains lit
when gas valve
knob is pushed
in, but goes out
when released.

B. If the above does not correct the

problem, the probable causes are a
weak gas valve pilot magnet, pilot
generator low millivolt output, or
a high-limit thermostat stuck open.

B. Call FASC.

A. Thermostat out of calibration.

A. Check calibration of thermostat in

accordance with procedures in
Section 4.2 of this manual.

Thermostat
does not control
at set point.

B. Failed thermostat.

B. Call FASC.


Advertising