Furuno 1834C-BB User Manual

Page 187

Advertising
background image

7. CUSTOMIZING YOUR UNIT

7-32

Sounder system setup menu description

Item Description

Settings

Fish Alarm

Level

Sets the fish alarm sensitivity; that is,

the minimum echo strength which will

trigger the fish alarms.

High: Orange and stronger echoes

trigger the alarm.*
Medium: Yellow and stronger echoes

trigger the alarm.*
Low: Green and stronger echoes

trigger the alarm.*

* = 8-color display

Transmission Turns TX power on/off.

On, Off

TVG

(HF,LF)

TVG (Time Varied Gain) compensates

for propagation attenuation of the

ultrasonic waves. It does this by

equalizing echo presentation so that

fish schools of the same size appear in

the same density in both shallow and

deep waters. In addition, it reduces

surface noise. Note that if the TVG

level is set too high short range

echoes may not be displayed.

0-9

Echo Offset

(HF, LF)

If the on-screen echo level appears to

be too weak or too strong and the

level cannot be adjusted satisfactorily

with the gain control, adjust echo

offset to compensate for too weak or

too strong echoes.

-50 - +50

Bottom Level

(HF, LF)

If the depth indication is unstable in

automatic operation or the bottom

echo cannot be displayed in

reddish-brown by adjusting the gain

control in manual operation, you may

adjust the bottom echo level detection

circuit, for both HF and LF, to stabilize

the indication. Note that if the level is

set too low weak echoes may be

missed and if set too high the depth

indication will not be displayed.

-100 - +100

KP Pulse

Selects source of keying pulse.

Internal, External (See installation

manual.)

Smoothing

Smoothes echoes to present stable

display. The higher the setting the

greater the smoothing.

SM1-SM4, OFF

TLL Output

Outputs current position to plotter

where it is marked with TLL mark. Use

soft key to output TLL.

ON, OFF

(Con’t on next page)