Furuno 1834C-BB User Manual

Page 223

Advertising
background image

SP - 4

5 PLOTTER

FUNCTION

5.1 Projection

Mercator

5.2 Usable Area

85 latitude or below

5.3 Effective Area

211.2 x 158.4 mm

5.4 Display pixels

640 x 480 dots

5.5 Position

Indication

Latitude/longitude, Loran C LOP or DECCA LOP

5.6 Effective Projection Area 0.125 nm to 1,024 nm (at equatorial area)
5.7 Track Display

Plot interval: by time (1 sec. to 99 min. 59 sec.) or

by distance (0 to 99.9 nm)

5.8 Colors

Red, yellow, green purple, light-blue, blue, white

5.9 Memory Capacity

Track/mark: 8000 points, Waypoint: 999 points

5.10 Storage Capacity

Simple route: 200 routes with 35 waypoints each


6 POWER

SUPPLY

6.1 Rated

Voltage/Current

M1824C-BB

12-24 VDC: 5.5-2.7 A

M1834C-BB

12-24 VDC: 5.3-2.6 A

M1934C-BB (24rpm)

12-24 VDC: 5.6-2.7 A

M1934C-BB (48rpm)

12-24 VDC: 7.5-3.6 A

M1944C-BB (24rpm)

12-24 VDC: 6.3-3.1 A

M1944C-BB (48rpm)

12-24 VDC: 8.1-3.8 A

M1954C-BB (24rpm)

12-24 VDC: 8.6-4.3 A

M1954C-BB (48rpm)

12-24 VDC: 10.3-5.1 A

M1964C-BB (24rpm)

12-24 VDC: 10.1-5.0 A

M1964C-BB (48rpm)

12-24 VDC: 11.6-5.6 A

6.2 Rectifier (option)

100-115/220-230 VAC, 1 phase, 50/60 Hz


7 ENVIRONMENTAL

CONDITION

7.1 Ambient Temperature Antenna Unit: -25°C to +70°C

Processor Unit and Control Unit: -15°C to +55°C

Power Supply Unit: -15°C to +55°C

7.2 Relative Humidity

93 % or less at +40°C

7.3 Waterproofing

Antenna Unit: IPX6

Control Unit: IPX5 (Front panel), IPX2 (Rear panel)

Processor Unit, Power Supply Unit: IPX0

7.4 Vibration IEC 60945-4

th

- 2 Hz-5Hz and up to 13.2 Hz with an excursion of ±1 mm ±10%

(7 m/s

2

maximum acceleration at 13.2 Hz);

- above 13.2 Hz and up to 100 Hz with a constant maximum

acceleration of 7 m/s

2

.