Installation – FMI SVYD18NRA User Manual

Page 11

Advertising
background image

www.fmiproducts.com

113084-01L

11

INSTALLATION

Continued

WARNING: Never connect

natural gas heater to private (non-

utility) gas wells. This gas is com-

monly known as wellhead gas.

Installation Items Needed
Before installing heater, make sure you have
the items listed below.
• external regulator - propane/LP only (sup-

plied by installer)

• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* A equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge
connection. Purchase the optional equipment
shutoff valve from your dealer.
The gas inlet connection for the stove heater
is located on the lower right-hand side of stove
when viewed from the front of unit. The gas con-
nection can be made either through the bottom
right side or through the lower back opening as
illustrated in Figure 8. Make sure gas log heater
is secured to stove cavity assembly.
For propane/LP units, installer must supply
an external regulator. The external regulator
will reduce incoming gas pressure. You must
reduce incoming gas pressure to between 11"
and 14" of water. If you do not reduce incom-
ing gas pressure, heater regulator damage
could occur. Install external regulator with
the vent pointing down as shown in Figure 9.
Pointing the vent down protects it from freez-
ing rain or sleet.

CAUTION: Use only new,

black iron or steel pipe. Inter-

nally-tinned copper tubing may

be used in certain areas. Check

your local codes. Use pipe of

1/2" diameter or greater to allow

proper gas volume to heater. If

pipe is too small, undue loss of

volume will occur.

Figure 8 - Gas Regulator Location and

Gas Line Access Into Stove Cabinet

Gas Inlet
Connection
Access

Gas Log Heater

Back View

Side View

Figure 9 - External Regulator With Vent

Pointing Down

Back Stove
Panel

Stove Unit Front

Propane/LP
Supply Tank

External
Regulator
with vent
Pointing
Down

Installation must include a equipment shutoff
valve, union and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up.
NPT tap must be upstream from heater (see
Figure 10, page 12).
IMPORTANT: Install equipment shutoff valve
in an accessible location. The equipment
shutoff valve is for turning on or shutting off
the gas to the appliances.
Check your building codes for any special
requirements for locating equipment shutoff
valve to fireplaces.
Apply pipe joint sealant lightly to male threads.
This will prevent excess sealant from going
into pipe. Excess sealant in pipe could result
in clogged heater valves.

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We recommend that you install a sediment trap
in supply line as shown in Figure 10, page 12.
Locate sediment trap where it is within reach
for cleaning. Install in piping system between
fuel supply and heater. Locate sediment trap
where trapped matter is not likely to freeze.
A sediment trap traps moisture and contami-
nants. This keeps them from going into heater
controls. If sediment trap is not installed or is
installed wrong, heater may not run properly.