POSSIBLE CAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too

low

3. Thermopile leads disconnect-

ed or improperly connected

4. Burners will not come on in

remote position

1. Manifold pressure is too

low

2. Burner orifice clogged

1. Burner orifice is clogged or

damaged

2. Damaged burner
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective
3. Residues from manufacturing

processes and logs curing

1. Not enough combustion/

ventilation air

1. Turning control knob to HI

position when burner is
cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice

1. Improper log placement

2. Drafts or other air currents

affecting flame pattern

3. Air holes at burner inlet

blocked

4. B u r n e r f l a m e h o l e s

blocked

REMEDY

1. Clean burner (see Cleaning

and Maintenance, page 17)
or replace burner orifice

2. Contact local propane/LP

or natural gas company

3. Reconnect leads (see Wir-

ing Diagram, page 21)

4. Replace battery in transmit-

ter and hand-held remote

1. Contact local propane/LP

or natural gas company

2. Clean burner (see Cleaning

and Maintenance, page 17)
or replace burner orifice

1. Clean burner (see Cleaning

and Maintenance, page 17)
or replace burner orifice

2. Replace damaged burner
3. Replace gas control

1. Check burner for dirt and

debris. If found, clean
burner (see Cleaning and
Maintenance
, page 17)

2. Replace gas control
3. Problem will stop after a few

hours of operation

1. Refer to Air for Combustion

and Ventilation require-
ments (page 5)

1. Turn control knob to LO

position and let warm up
for a minute

2. Operate burner until air is

removed from line. Have gas
line checked by local propane/
LP or natural gas company

3. Observe minimum installation

clearances (see page 8)

4. Clean burner (see Cleaning

and Maintenance, page 17)
or replace burner orifice

1. Properly locate logs (see

Installing Gas Log Into
Stove,
page 10)

2. Eliminate source of drafts

around heater

3. Clean out air holes at burn-

er inlet. Periodically repeat
as needed

4. Remove blockage or re-

place burner

OBSERVED PROBLEM

Burner does not light after
ODS/pilot is lit

Delayed ignition burner

Burner backfiring during
combustion

Slight smoke or odor during
initial operation

Moisture/condensation no-
ticed on windows

Heater produces a whistling
noise when burner is lit

Dark residue on logs or inside
of fireplace

TROUBLESHOOTING

Continued