Installation – FMI SVYD18NRA User Manual

Page 8

Advertising
background image

www.fmiproducts.com

113084-01L

8

INSTALLATION

IMPORTANT: Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation
air may cause mildew to form from too much
moisture. See Air for Combustion and Ventila-
tion
, page 5.

CHECK GAS TYPE

Use only the correct type of gas (natural or
propane/LP). If your gas supply is not the
correct gas type, do not install heater. Call
dealer where you bought heater for proper
type heater.

WARNING: This appliance is

equipped for either natural gas

or propane/LP gas but not both.

Gas type is indicated on the rat-

ing plate. Field conversion is not

permitted.

CLEARANCES TO COMBUSTIBLES

WARNING: Maintain the

minimum clearances. If you can,

provide greater clearances from

floor, ceiling and adjoining side

and back walls.

Carefully follow the instructions below. This
stove is a freestanding unit designed to set
directly on the floor. IMPORTANT: You must
maintain minimum wall and ceiling clearances
during installation. The minimum clearances
are shown in Figure 4, page 9. Measure from
outermost point of stove top.

Minimum Wall and Ceiling Clearances
(see Figure 4, page 9)
A. Clearances from outermost point of stove

top to any combustible side wall should
not be less than 12".

B. Clearances from outermost point of stove

top to any combustible back wall should
not be less than 6" (includes corner instal-
lations).

C. Clearances from the stove top to the ceil-

ing should not be less than 48".

NOTICE: This heater is intended

for use as supplemental heat.

Use this heater along with your

primary heating system. Do not

install this heater as your pri-

mary heat source. If you have a

central heating system, you may

run system’s circulating blower

while using heater. This will help

circulate the heat throughout the

house. In the event of a power

outage, you can use this heater

as your primary heat source.

WARNING: A qualified ser-

vice person must install fire-

place. Follow all local codes.

WARNING: Never install the

heater

• in a bedroom or bathroom

• in a recreational vehicle

• where curtains, furniture,

clothing or other flammable

objects are less than 42" from

the front, top or sides of the

heater

• in high traffic areas

• in windy or drafty areas

CAUTION: This heater cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to heater. Installing

heater next to vinyl or cloth wall

coverings or operating heater

where impurities (such as, but

not limited to, tobacco smoke,

aromatic candles, cleaning flu-

ids, oil or kerosene lamps, etc.) in

the air exist, may discolor walls

or cause odors.

Advertising