2 replacement of fuse, resetting the breaker, Warning – Furuno UAIS TRANPONDER FA-150 User Manual

Page 77

Advertising
background image

3. MAINTENANCE, TROUBLESHOOTING

3-2

3.2

Replacement of Fuse, Resetting the Breaker

3.2.1

Replacement of fuse

The power cable for the monitor unit contains a 3A fuse which protects the
equipment from overvoltage, reverse polarity and equipment fault. If the power
cannot be turned on, check if the fuse has blown. If the fuse has blown, find the
cause before replacing the fuse. If the fuse blows again after replacement,
contact your dealer for advice.

Part Type Code

No.

Fuse

FGBO-A 3A AC125V 000-549-063

WARNING

Use the proper fuse.

Use of a wrong fuse can cause fire or
result in damage to the equipment.

3.2.2

Resetting the breaker

If the power cannot be turned on, the BREAKER button on the rear panel of the
transponder unit may have activated. The BREAKER button pops out when
overvoltage, reverse polarity or equipment fault is detected, to protect the
system from damage. If the button pops out, find the reason before pushing it
in to restore normal operation.

Breaker

BREAKER

10A

GPS ANT

PC

VHF ANT


Advertising