Ap-8, Sentence data – Furuno UAIS TRANPONDER FA-150 User Manual

Page 97

Advertising
background image

APPENDIX

AP-8

Digital Interface (IEC 61162-1 Edition 2, IEC 61162-2)

Sentence data

Input sentences

ABM, ACA, ACK, AIR, BBM, DTM, GBS, GGA, GLL, GNS, HDT, LRF, LRI, OSD,
PIWWIVD, PIWWSPW, PIWWSSD, PIWWVSD, RMC, ROT, SSD, VBW, VSD, VTG

Output sentences

ABK, ACA, ACS, ALR, LRF, LR1, LR2, LR3, TXT, PIWWSPR, VDM, VDO

Transmission interval

ABK: With each event
ACA, ACS: At RX
ALR: 30 s during alarm, 2 min normally no alarm
LRF, LR1, LR2, LR3: At RX
TXT: Each update
VDM: At RX
VDO: 1 s

Load requirements as listener

Isolation: Provided
Input Impedance: Input Impedance: 110 ohms (130K ohms without jumper plug)
Max. Voltage:

±14 V to GNDiso

Threshold:

±0.2 V (A-B)

Output drive capability

Differential driver output
R=50 ohm 2 v min.
R=27 ohm 1.5 V min.

Driver short-circuit current
60 mA min. 150 mA max.

Data transmission

Data is transmitted in serial asynchronous form in accordance with the standard
referenced in 2.1 of IEC 61162-1/2. The first bit is a start bit and is followed by data bits,
least-significant-bit as illustrated below.

The following parameters are used:
Baud rate: 38.4 Kbps /4800 bps
Data bits: 8 (D7 = 0), parity none
Stop bits: 1

D0 D1 D2 D3 D4 D5 D6 D7

Start
bit

Stop
bit

Data bits

Advertising