Furuno Sc 50 User Manual

Page 15

Advertising
background image

1. INSTALLATION

1-5

3. Coat exposed parts of nuts, bolts and washers with silicone sealant.

Radome
base

Coat with
silicone sealant.

Platform

Coating bolt, nut and washers with silicone sealant

4. Connect the three coaxial cables coming from the antenna unit to the

appropriate coaxial cables on the antenna cable, referring to the table below.

Cable from antenna

(no. marked on cable)

Cable

TTPX6-3D2V-15M

ANT 1

No color

ANT 2

Yellow

ANT 3

Red

For TNC-PS-3D-15, cable labels are provided from cable 1, 2 and 3 to
differentiate between then.

5. Cover the antenna connectors with vulcanizing tape and vinyl tape, for

waterproofing. Tie tape ends with a cable tie.

Waterproofing the antenna connector

6. Set the joints of the coaxial cables into the cavity in the antenna base.
7. Pass two cable ties (long life, temperature resistant type, local supply)

through the hole shown in the figure below. Fasten them at the locations
shown in the figure below.

Cable Tie

How to fasten the antenna cable

Advertising