Furuno Sc 50 User Manual

Page 33

Advertising
background image

1. INSTALLATION

1-23

1.7.2

Fabrication of cables

Cable

Sectional view, fabrication

Power

cable

DPCY-1.5

(or

equivalent)

Conductor

S = 1.5 mm

φ

= 1.56 mm

2

Armor

Sheath

φ

=

11.7 mm

SECTIONAL VIEW

50

6

Armor

Cut the sheath.

Vinyl tape

Sheath

15

FABRICATION

Crimp-on lug
FV1.25-5

50

Lay in clamp
where paint
was removed.

Cable for

IEC 61162

format

equipment

(JIS cable

TTYCS-1

or

equivalent)

Cable for

AD-10

format

equipment

((JIS cable

TTYCS-1Q

or

equivalent)

Conductor

S = 0.75 mm

φ

= 1.11 mm

2

Armor

Shield

Sheath

φ

=

10.1 mm

SECTIONAL VIEW (TTYCS-1)

Conductor

S = 0.75 mm

φ

= 1.11 mm

2

Armor

Shield

Sheath

φ

=

11.3 mm

SECTIONAL VIEW (TTYCS-1Q)

3

80

Armor

Braided shield

8

Twist and cut.

6

Ground wire (70)

Solder

Four cores on TTYCS-1Q

10

15

Remove paint by
40 mm, clamp this
part in cable clamp.

Vinyl tape

Ground wire: Fasten to fixing screw on pcb.

FABRICATION

NOTE ON WIRING
1) Ground both this unit
and external equipment.

2) Fabricate braided shield of external equipment as follows:
- IEC 61162-1 input, AD-10 input (photo coupler): Connect to FG(frame ground).
- IEC 61162-2 input (RS-422/485): Connect to SG(signal ground).

Note: The power section of this equipment is insulated so the potential of SG and FG are the
same. If the shielding is not properly done, the data output IC may be damaged.